SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
649
2 Parameters
2.2 List of parameters
Description:
Display parameter for output pulse Q of instance PST 1 of the pulse extension element.
Description:
Setting parameter for the run-time group in which the instance PST 1 of the pulse extension element is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PST 1 within the run-time group set in p20186.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for set input S and reset input R of instance RSR 0 of the RS flipflop.
Index:
[0] = Set S
[1] = Reset R
r20185
BO: PST 1 output Q / PST 1 output Q
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7234
Min Max
Factory
setting
- - -
p20186
PST 1 run-time group / PST 1 RTG
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7234
Min Max
Factory
setting
5 9999
9999
p20187
PST 1 run sequence / PST 1 RunSeq
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7234
Min Max
Factory
setting
0 7999
500
p20188[0...1]
BI: RSR 0 inputs / RSR 0 inputs
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7240
Min Max
Factory
setting
- - 0