GT25 General Description
Thank you for purchasing the GOT2000 Series.
GT2512-STBA
GT2510-VTBD
GT2508-VTBD
GT2512-STBD
GT2510-VTWD
GT2508-VTWD
GT2510-VTBA
GT2508-VTBA
GT2510-VTWA
GT2508-VTWA
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL
GT25-U-GD-E
Model
code
1D7MN4
IB(NA)-0800537ENG-B(1410)MEE
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Note that the
CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Some failures of the GOT, communication unit or cable may keep the outputs
on or off.
Some failures of a touch panel may cause malfunction of the input objects
such as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious
accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
The GOT backlight failure disables the operation on the touch switch(s).
When the GOT backlight has a failure, the POWER LED blinks (orange/blue)
and the display section dims. In such a case, the input by the touch switch(s)
is disabled.
The display section of the GOT is an analog-resistive type touch panel.
When multiple points of the display section are touched simultaneously, an
accident may occur due to incorrect output or malfunction.
Do not touch the display section in 2 points or more simultaneously.
If you touch the display section simultaneously in 2 points or more, the switch
that is located around the center of the touched point, if any, may operate.
Doing so may cause an accident due to incorrect output or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT, or turn on the
unit again after shutting off the power as soon as possible.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
For bus connection : The CPU becomes faulty and the GOT becomes
inoperative.
For other than bus connection : The GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
WARNING
CAUTION
WARNING
[MOUNTING PRECAUTIONS]
Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in
Class I, Division 2, Groups A, B, C and D hazardous locations, or
nonhazardous locations only.
This mark indicates that the product is certified for use in the Class I,
Division2 environment where flammable gases, vapors, or liquids are not
likely to exist under normal conditions.
When using the products in the Class I, Division 2 environment, observe the
following to reduce the risk of explosion.
• This device is open-type and is to be installed in an enclosure suitable for
the environment and require a tool or key to open.
• Warning - Explosion Hazard - Substitution of any component may impair
suitability for Class I, Division 2.
• Warning - Explosion Hazard - Do not disconnect equipment unless power
has been removed or the area is known to be non-hazardous.
• The side interface and extension interface of this equipment cannot be used
in Class I, Division 2 environments.
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être
utilisés en Class I, Division 2, local dangereux de groupe A, B, C et D, ou
uniquement en local non dangereux.
Ce logo indique que le produit est homologué pour utilisation en
environnement de Class I, Division 2 où, dans des circonstances anormales,
il peut y avoir présence de gaz, vapeurs ou liquides inflammables.
Si le produit est utilisé en environnement de Class I, Division 2, observer les
précautions suivantes pour réduire le risque d'explosion.
•
Cet appareil est de type ouvert et il doit être installé dans une enceinte
appropriée à l'environnement et ne pouvant être ouverte qu'au moyen
d'une clé ou d'un outil.
•
Avertissement - Danger d'explosion - Toute substitution de composant
peut compromettre l'aptitude à l'utilisation en Class I, Division 2.
•
Avertissement - Danger d'explosion - Ne pas déconnecter l'équipement
quand le circuit est sous tension, ni avant de d'être assuré de l'absence
d'atmosphère inflammable.
•
L’interface latérale et l’interface d’extension de cet équipement ne
peuvent être utilisées dans les environnements de Classe I, Division 2.
Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm apart.
Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or
driver.
Doing so can result in a damage or failure of the display section.
When the GOT is connected to the Ethernet network, the available IP
address is restricted according
to the system configuration.
• When multiple GOTs are connected to the Ethernet network :
Do not set the IP address (192.168.3.18) for the GOTs and the controllers in
the network.
• When a single GOT is connected to the Ethernet network :
Do not set the IP address (192.168.3.18) for the controllers except the GOT
in the network.
Doing so can cause the IP address duplication. The duplication can
negatively affect the communication of the device with the IP address
(192.168.3.18).
The operation at the IP address duplication depends on the devices and the
system.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the option unit onto/from the GOT.
Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product
damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head
screwdriver No.2.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or the GOT.
When mounting a unit on the GOT, tighten the mounting screws in the
following specified torque range.
When loading the communication unit or option unit other than wireless LAN
unit to the GOT, fit it to the connection interface of the GOT and tighten the
mounting screws in the specified torque range (0.36 N•m to 0.48 N•m) with a
Phillips-head screwdriver No.2.
When loading the wireless LAN unit to the GOT, fit it to the side interface of
GOT and tighten the mounting screws in the specified torque range (0.10
N•m to 0.14 N•m) with a Phillips-head screwdriver No.1.
When the GOT is installed vertically, its side interface is positioned on the
bottom.To prevent the falling of the wireless LAN communication unit from the
side interface, install or remove the unit while holding it with hands.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
WARNING
CAUTION
WARNING
CAUTION
[WIRING PRECAUTIONS]
[WIRING PRECAUTIONS]
[TEST OPERATION PRECAUTIONS]
[STARTUP/MAINTENANCE PRECAUTIONS]
When closing the USB environmental protection cover, fix the cover to the
GOT by pushing the [PUSH] mark on the latch firmly to comply with the
protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may
not be removed.
Operate and store the GOT in environments without direct sunlight, high
temperature, dust, humidity, and vibrations.
When using the GOT in the environment of oil or chemicals, use the
protective cover for oil.Failure to do so may cause failure or malfunction due
to the oil or chemical entering into the GOT.
Be sure to shut off all phases of the external power supply used by the
system before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
Make sure to ground the FG terminal and LG terminal of the GOT power
supply section to the protective ground conductors dedicated to the GOT with
a ground resistance of 100
Ω
or less.
When tightening the terminal screws, use a Phillips-head screwdriver No.2.
Terminal screws which are not to be used must be tightened always at torque
0.5 N•m to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless
terminals.
Use applicable solderless terminals and tighten them with the specified
torque. If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure
Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 N•m to 0.8 N•m). Undertightening can cause a short circuit
or malfunction.Overtightening can cause a short circuit or malfunction due to
the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.Before starting system operation, be sure
to peel this label because of heat dissipation.
Plug the communication cable into the GOT interface or the connector of the
connected unit, and tighten the mounting screws and the terminal screws in
the specified torque range.Undertightening can cause a short circuit or
malfunction.Overtightening can cause a short circuit or malfunction due to the
damage of the screws or unit.
Plug the QnA/ACPU/Motion controller(A series) bus connection cable by
inserting it into the connector of the connected unit until it "clicks".
After plugging, check that it has been inserted snugly.
Not doing so can cause a malfunction due to a contact fault.
Before performing the test operations of the user creation monitor screen
(such as turning ON or OFF bit device, changing the word device current
value, changing the settings or current values of the timer or counter, and
changing the buffer memory current value), read through the manual
carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system.
False output or malfunction can cause an accident.
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Correctly connect the battery connector.Do not charge, disassemble, heat,
short-circuit, solder, or throw the battery into the fire.Doing so will cause the
battery to produce heat, explode, or ignite, resulting in injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.Not switching the power off in all phases can
cause a unit failure or malfunction.Undertightening can cause a short circuit
or malfunction.Overtightening can cause a short circuit or malfunction due to
the damage of the screws or unit.
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull from
the cable portion.Doing so can cause the unit or cable to be damaged or can
cause a malfunction due to a cable connection fault.
CAUTION
WARNING
CAUTION
CAUTION
WARNING
WARNING
CAUTION
[TOUCH PANEL PRECAUTIONS]
[PRECAUTIONS WHEN THE DATA STORAGE IS IN
USE]
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Do not drop the module or subject it to strong shock. A module damage may
result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the
battery.If the battery is dropped or given an impact, dispose of it without
using.
Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children.Do not disassemble and do not dispose of in fire.
Be sure to shut off all phases of the external power supply before replacing
the battery or using the dip switch of the terminating resistor.Not doing so can
cause the unit to fail or malfunction by static electricity.
For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position
may occur as the period of use elapses.
When any difference between a touched position and the object position
occurs, execute the touch panel calibration.
When any difference between a touched position and the object position
occurs, other object may be activated.
This may cause an unexpected operation due to incorrect output or
malfunction.
If the SD card is removed from drive A of the GOT while being accessed by
the GOT, the GOT may stop processing data for about 20 seconds.The GOT
cannot be operated during this period. The functions that run in the
background including a screen updating, alarm, logging, scripts, and others
are also interrupted.Since this interruption makes an impact to the system
operation, it might cause failure.After checking the light off of SD card access
LED, remove the SD card.
If the data storage is removed from the GOT while being accessed by the
GOT, the data storage and files may be damaged.Before removing the data
storage from the GOT, check the SD card access LED, system signal, or
others to make sure that the data storage is not accessed.
When inserting a SD card into the GOT, make sure to close the SD card
cover. Failure to do so causes the data not to be read or written.
When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out.Failure to do so may cause the SD card to drop
from the GOT, resulting in a failure or break.
When inserting a USB device into a USB interface of the GOT, make sure to
insert the device into the interface firmly.Failure to do so may cause the USB
device to drop from the GOT, resulting in a failure or break
Before removing the USB device from the GOT, follow the procedure for
removal on the utility screen of the GOT. After the successful completion
dialog is displayed, remove the USB device by hand carefully.Failure to do so
may cause the USB device to drop from the GOT, resulting in a failure or
break.
When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to
the local regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
battery directive in the EU member states.)
When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
regulated models.)
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of this manual, as they are
precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden
packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other
than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
CAUTION
CAUTION
WARNING
CAUTION
CAUTION
CAUTION
Manual
The following shows manuals relevant to this product.
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the
drawing software used.
For relevant manuals, refer to the Help or the PDF manuals stored in the DVD-
ROM for the drawing software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (http://www.MitsubishiElectric.co.jp/fa/).
© 2014MITSUBISHI ELECTRIC CORPORATION
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
Refer to the GOT2000 Series User’s Manual (Hardware) for the connection
instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User’s Manual (Hardware).
Packing List
The GOT product package includes the following:
1. FEATURES
(1) Abundant standard equipment
• Variety of connection with FA devices
• SD card interface compatible with the SDHC card having a large capacity
and allowing high-speed communication
• Connection with various peripheral devices with the USB host
(2) Improved usability
• Abundant troubleshooting
• Easy and clear screen creation
• PC-like operation screen
• Support for the vertical installation
(3) Enhanced compatibility with Mitsubishi FA devices
(4) Easy replacement]
(5) LED backlight
(6) Various extended functions supported
2. Part Names and Settings
The following shows the part names for GT2512
,
GT2510 and GT2508.
Detailed Manual
Manual name
Manual number
(Model code)
GOT2000 Series User’s Manual
(Hardware)
SH-081194ENG
(1D7MJ5)
GOT2000 Series User’s Manual (Utility)
SH-081195ENG
(1D7MJ6)
Relevant Manuals
Description
Quantity
GT25
1
Battery (GT11-50BAT) (Attached to the GOT)
1
Installation fitting
4
GT25 General Description (This manual)
1
GT25 本体概要説明書
1
GT2512
1)2)
5)
22)
17)
7)
16)
8)
9)
10)
11)
12)
13)
14)
21)20) 19)
6)
6)
6)
6)
3)4)
15)
18)
No.
Name
Description
1)
Display screen
Displays the utility and the user-created screen.
2)
Touch Pane
For operating the touch switches in the utility and the user-
created screen
3)
USB interface
(Host/Front face)
For connecting a USB mouse, connecting a USB keyboard,
data transfer, and data storage
(connector type: TYPE-A)
(Only GT2512-STBA/D, GT2510-VTBA/D
and
GT2508-
VTBA/D)
4)
USB interface (Device
/Front face)
For connecting a personal computer (connector type: Mini-
B)
(Only GT2512-STBA/D, GT2510-VTBA/D
and
GT2508-
VTBA/D)
5)
POWER LED
Lit in blue
: Power is properly supplied.
Lit in orange
: Screen saving
Blinks in orange/blue
: Backlight failure
Not lit
: Power is not supplied
6)
Unit installation fitting
Mounting fixtures for fixing the GOT to the control panel
7)
Reset switch
Hardware reset switch
8)
Installation switch
Used for OS installations at the GOT startup
9)
SD card access LED
Lit: SD card mounted
Blinking: SC card accessed
No lit: SD card not mounted or SD card mounted
(removable)
10) SD card interface
For installing a SD card
11) SD card cover
With a switching function for accepting and stopping the
access to the SD card
When the cover is opened : Access is prohibited
When the cover is closed : Access is allowed
12) Battery holder
Houses the battery
13) Side interface
For installing a communication unit
14)
USB interface
(Host/Back face)
For connecting a USB mouse, connecting a USB keyboard,
data transfer, and data storage
(connector type: TYPE-A)
15)
Hole for attaching a
cable clamp
Hole for attaching a cable clamp for preventing USB cable
from being pulled out
(Recommended product: RSG-130-V0 made by
KITAGAWA INDUSTRIES CO.,LTD)
16)
Terminating resistor
setting switch
(Inside cover)
For switching on and off of the terminating resistor for the
RS-422/485 communication port (Default (Off))
17) Extension interface
For installing a communication unit or an option unit
18) Vertical installation
arrow mark
For the vertical installation, install the GOT so that the arrow
points upward.
19) Power terminal
Power input terminal, LG terminal, FG terminal
20) Ethernet interface
For communicating with a controller or connecting a
personal computer (connector type: RJ-45 (modular jack))
21) RS-232 interface
For communicating with a controller (Connector type: D sub
9-pin (male))
22) RS-422/485 interface
For communicating with a controller (Connector type: D sub
9-pin (female))
23)
USB interface (Device/
Back face)
For connecting personal computers (connector type: Mini-B)
(Only GT2510-VTWA/D, GT2508-VTWA/D)
GT2510
12)
9)
10)
11)
13)
14)
22)21)20) 19)
6)
6)
17)
7)
16)
8)
6)
6)
1)2)
18)
3)4)
23)
15)
GT2508
9)
10)11)12)
16)
13)
14)
22)21)20) 19)
6)
6)
17)
7)
8)
6)
6)
1)2)
5)
3)4)
15)23)
18)
3. Specifications
3.1 General Specifications
*1: The operating ambient temperature includes the temperature
inside the
enclosure of the control panel to which the GOT is
installed.
La température ambiante de fonctionnement inclut la température à l'intérieur
du boîtier du tableau de commande sur lequel le GOT est installé.
*2: When mounting a MELSECNET/H communication unit (GT15-J71LP23-25,
GT15-J71BR13), or CC-Link communication unit (GT15-J61BT13), the
operating ambient temperature must be reduced
5
against the maximum
values described in general specifications.
Lors du montage d'un module communication MELSECNET/H (GT15-
J71LP23-25, GT15-J71BR13) ou du module de communication CC-Link
(GT15-J61BT13), la température ambiante de fonctionnement doit être réduite
de 5 par rapport aux valeurs maximales décrites dans les spécifications
générales.
*3: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0m (0ft.).
Failure to observe this instruction may cause a malfunction.
When an air purge is made inside the control panel by adding pressure, there
may be a clearance between the surface sheet and the screen making it difficult
to use the touch panel, or the sheet may come off.
*4: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*5: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT25
.
Item
Specifications
Operating ambient
temperature
*1
Température
ambiante de
fonctionnement
*1
0 to 55
*2
0 à 55
*2
Storage ambient
temperature
-20 to 60
Operating ambient
humidity
10 to 90% RH, non-condensing
Storage ambient
humidity
10 to 90% RH, non-condensing
Vibration resistance
Complian
t with JIS
B 3502
and IEC
61131-2
Frequency Acceleration
Half-
amplitude
Sweep
count
Under
intermitten
t vibration
5 to 8.4Hz
-
3.5mm
10 times
each in X,
Y and Z
directions
8.4 to150Hz
9.8m/s
2
-
Under
continuou
s vibration
5 to 8.4Hz
-
1.75mm
-
8.4 to 150Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
2
(15G),
3 times each in X, Y and Z directions
Operating
atmosphere
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and direct sunlight (Same as storage atmosphere)
Operating altitude
*3
2000 m (6562 ft) max.
Installation location
Inside control panel
Overvoltage
category
*4
II or less
Pollution degree
*5
2 or less
Cooling method
Self-cooling
Grounding
Type D grounding (100
Ω
or less).
Connect to panel if unable to ground.
Point
Refer to the GOT2000 Series User’s Manual (Hardware) for details on the performance
specifications of each GOT.
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
3.2.1 For GOTs powered from the 100 to 240VAC
power supply
3.2.2 For GOTs powered from the 24VDC power
supply
3.3 External Dimensions
Item
Specifications
GT2512-STBA
GT2510-VTBA,
GT2510-VTWA
GT2508-VTBA,
GT2508-VTWA
Power supply voltage
Power supply voltage AC100 to 240VAC (+10%, -15%)
Power frequency
50/60Hz
5%
Max. apparent power
80VA
80VA
70VA
Power
consum
ption
maximum load
35W or less
34W or less
31W or less
Stand alone
14W
12W
11W
Stand alone with
backlight off
7W
7W
7W
Inrush current
60A or less (2ms, operating ambient temperature 25,
maximum load)
Allowable momentary power
failure time
20 ms or less (100VAC or more)
Noise immunity
1,500Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60Hz
noise frequency)
Dielectric withstand voltage
1500VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a
500V DC insulation resistance tester
Applicable wire size
0.75[mm
2
] to 2[mm
2
]
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5[N•m] to 0.8[N•m]
Item
Specifications
GT2512-STBD
GT2510-VTBD,
GT2510-VTWD
GT2508-VTBD,
GT2508-VTWD
Power supply voltage
DC24V (+25%, -20%)
Power
consum
ption
maximum load
37W or less
33W or less
31W or less
Stand alone
13W
10W
8W
Stand alone with
backlight off
6W
6W
Inrush current
5A or less (20ms, operating ambient temperature 25,
maximum load)
Allowable momentary power
failure time
10 ms or less
Noise immunity
500Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60Hz
noise frequency)
Dielectric withstand voltage
350VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a
500V DC insulation resistance tester
Applicable wire size
0.75[mm
2
] to 2[mm
2
]
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5[N•m] to 0.8[N•m]
GT2510
GT2508
303 (11.93)
241 (9.49)
166 (6.54)
226 (8.90)
171.6
(6.76)
208 (8.19)
228 (8.98)
288 (11.34)
218 (8.58)
199 (7.83)
10
(0.39)
10
(0.39)
175 (6.89)
194 (7.64)
10
(0.39)
10
(0.39)
52
(2.05)
6
(0.24)
52
(2.05)
6
(0.24)
Unit : mm (inch)
37.5
(1.48)
37.5
(1.48)
GT2512
316 (12.44)
246 (9.69)
227 (8.94)
10
(0.39)
10
(0.39)
52
(2.05)
6
(0.24)
241 (9.49)
241 (9.49)
301 (11.85)