SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
557
2 Parameters
2.2 List of parameters
Description:
Sets the denominator for the gearbox between the motor and the load.
Index:
[0] = Gearbox 1
[1] = Gearbox 2
[2] = Gearbox 3
[3] = Gearbox 4
[4] = Gearbox 5
[5] = Gearbox 6
[6] = Gearbox 7
[7] = Gearbox 8
Dependency:
Refer to: p9522
Notice:
It is not possible to change over the gearbox stages. Gearbox 1 (index 0) is always active.
Description:
Sets the numerator for the gearbox between the motor and the load.
Index:
[0] = Gearbox 1
[1] = Gearbox 2
[2] = Gearbox 3
[3] = Gearbox 4
[4] = Gearbox 5
[5] = Gearbox 6
[6] = Gearbox 7
[7] = Gearbox 8
Dependency:
Refer to: p9521
Notice:
It is not possible to change over the gearbox stages. Gearbox 1 (index 0) is always active.
Note:
In the case of encoderless monitoring functions, the pole pair number must be multiplied by the numerator of the
gearbox ratio.
Example:
Gearbox ratio 1:4, pole pair number (r0313) = 2
--> p9521 = 1, p9522 = 8 (4 x 2)
Description:
Sets the limit values for the function "Safely Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
Refer to: p9563
Refer to: C01714
Note:
SLS: Safely Limited Speed
p9521[0...7]
SI Motion gearbox motor/load denominator (processor 1) / SI Mtn gear den P1
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 2147000000
1
p9522[0...7]
SI Motion gearbox motor/load numerator (processor 1) / SI Mtn gear num P1
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 2147000000
1
p9531[0...3]
SI Motion SLS limit values (processor 1) / SI Mtn SLS lim P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.01 [rpm]
100000.00 [rpm]
2000.00 [rpm]