vacon 100

ac drives

marine installation guide

®

®

Summary of Contents for 100X series

Page 1: ...vacon 100x vacon 100 ac drives marine installation guide...

Page 2: ......

Page 3: ...et door to hold on to and a hook to keep the cabinet door open The enclosed drives also have a cabinet heater as default The Vacon 100 and Vacon 100 FLOW are available in enclosure sizes MR4 MR12 and...

Page 4: ...VACON 4 TEL 358 0 201 2121 FAX 358 0 201 212 205...

Page 5: ...4 2 1 The maximum vibration 21 4 2 2 Installation safety in a marine environment 21 4 3 EMC requirements 21 4 3 1 Installing a drive in an IT network 22 4 3 2 Installing a drive in a grounded network...

Page 6: ...duct You can find the general approvals in the Installation Manual of your Vacon 100 product ABS the American Bureau of Shipping BV Bureau Veritas DNV GL Det Norske Veritas Germanischer Lloyd LR Lloyd...

Page 7: ...E See the complete list of warnings in the Installation Manual of your Vacon 100 product NOTE You can download the English and French product manuals with applicable safety warning and caution informa...

Page 8: ...h the marine option Enclosure size Weight kg Weight lb Wall mounted drive MR4 6 1 13 4 Wall mounted drive MR5 10 1 22 3 Wall mounted drive MR6 20 1 44 3 Wall mounted drive MR7 37 6 82 9 Wall mounted d...

Page 9: ...nnecessary long time When the springs are squeezed they can bounce suddenly and cause damage to the equipment A B A The lifting hole B The springs at the bottom WARNING Be careful when you lift the en...

Page 10: ...the Vacon 100 X product see its Installation Manual 4 1 1 DIMENSIONS OF THE WALL MOUNTED DRIVES 4 1 1 1 Dimensions of the wall mounted drive with the marine option MR4 17 0 67 345 13 58 313 12 32 129...

Page 11: ...e with the marine option MR5 17 0 67 441 17 36 406 15 98 144 5 67 214 8 43 115 4 53 4 x 6 0 24 Fig 3 Dimensions of the wall mounted drive with the marine option MR5 mm in MOUNTING VACON 11 24 HOUR SUP...

Page 12: ...ted drive with the marine option MR6 17 0 67 576 22 68 540 21 26 195 7 68 229 9 06 148 5 83 4 x 8 0 31 Fig 4 Dimensions of the wall mounted drive with the marine option MR6 mm in VACON 12 MOUNTING 4 T...

Page 13: ...e with the marine option MR7 17 0 67 680 26 77 645 25 39 237 9 33 259 10 20 190 7 48 4 x 8 0 31 Fig 5 Dimensions of the wall mounted drive with the marine option MR7 mm in MOUNTING VACON 13 24 HOUR SU...

Page 14: ...th the marine option MR8 39 1 54 1033 40 67 315 12 40 245 9 65 5 0 20 10 0 39 390 15 35 1111 43 74 4 x 11 0 43 Fig 6 Dimensions of the wall mounted drive with the marine option MR8 mm in VACON 14 MOUN...

Page 15: ...12 0 47 11 0 43 Fig 7 Dimensions of the wall mounted drive with the marine option MR9 mm in 4 1 2 DIMENSIONS OF THE ENCLOSED DRIVES Some options of the enclosed drives require additional cabinets For...

Page 16: ...13 0 51 383 15 08 4 x 12 0 47 2 x 13 0 51 335 13 19 548 21 57 936 36 85 2124 83 62 2170 85 43 13 0 51 672 26 46 0 15 0 59 446 17 56 A A 781 30 75 0 15 0 59 Fig 8 Dimensions of the enclosed drive with...

Page 17: ...06 646 25 43 548 21 57 936 36 85 2124 83 62 2170 85 43 672 26 46 0 15 0 59 A A 781 30 75 0 15 0 59 B B 13 0 51 548 21 57 13 0 51 4 x 12 0 47 Fig 9 Dimensions of the enclosed drive with the marine opt...

Page 18: ...548 21 57 A A 535 21 06 646 25 43 548 21 57 936 36 85 2124 83 62 2170 85 43 13 0 51 672 26 46 0 15 0 59 A A 781 30 75 0 15 0 59 4 x 12 0 47 13 0 51 Fig 10 Dimensions of the enclosed drive with the ma...

Page 19: ...0 548 21 57 548 21 57 1246 49 06 548 21 57 2124 83 62 2170 85 43 672 26 46 0 15 0 59 A A 781 30 75 0 15 0 59 13 0 51 13 0 51 4 x 12 0 47 1135 44 69 Fig 11 Dimensions of the enclosed drive with the mar...

Page 20: ...or deck zones A B D E E F G H C I 230 V 230 V 115 V 230 V 450 V G 3 M 3 M 3 G 3 M 3 Fig 12 The installation zones in a marine environment A Special power distribution zone B Propulsion systems bow thr...

Page 21: ...ake sure that you prevent contamination and condensation on the drive Before commissioning make sure that the product is clean and dry and that it fulfills the requirements of the Installation Manual...

Page 22: ...zone you must make an EMC plan refer to IEC 61800 3 Annex E The nature of the IT network minimizes the disturbance currents that circulate in the ground potential Thus you can achieve compatibility wi...

Page 23: ...an EMC plan refer to IEC 61800 3 Annex E In the EMC plan assess the required amount of high frequency filtering See the recommended amount of filtering in Table 4 You can use this table as a reference...

Page 24: ...R7 Attach the components of the marine option Use 4 pcs of 8 mm 0 31 in screws Tighten the screw so that it is tight but so that the bracket A does not deform For the other 2 screws B use a tightening...

Page 25: ...tion frame to the wall You can use screws or welding Attach the drive to the installation frame Use A 4 pcs of M10 x 25 mm screws tightened to a minimum torque of 40 Nm B 4 pcs of 10 mm washers C 6 pc...

Page 26: ...cessories bag to the holes in the cabinet door with M8 x 40 mm bolts and M8 nuts A The upper damper B M5 x 12 mm screws The picture shows an MR12 drive A B 2 MR8 To attach the upper damper use A An M8...

Page 27: ...he upper damper use A An M12 x 30 mm bolt tightened to a 60 70 Nm torque B A 12 mm plain washer C An M12 nut tightened to a 60 70 Nm torque B C A MOUNTING VACON 27 24 HOUR SUPPORT 358 0 201 212 575 EM...

Page 28: ...nstallation Manual of your Vacon 100 product Table 5 The maintenance intervals and tasks for the marine option Maintenance interval Maintenance task Regularly Do a check of the installation bolts of t...

Page 29: ......

Page 30: ...Document ID Rev A Sales code DOC INS100MA DLUK Vacon Ltd Member of the Danfoss Group Runsorintie 7 65380 Vaasa Finland www danfoss com...