TROUBLESHOOTING [POWER DOOR LOCK SYSTEM]
STEP
INSPECTION
ACTION
12
Make sure that driver’s side door is opened.
Connect keyless unit connector.
Connect volt-meter between keyless
connector terminal E and ground.
Perform following procedures
within 30
seconds:
0 Repeat following five times:
• Turn ignition switch to ON.
• Turn ignition switch to LOCK.
© Remove ignition key from steering lock.
(3) Repeat following three times:
• Push driver’s side door switch.
• Release driver’s side door switch.
M easure voltage at keyless unit connector
terminal E.
• 5 V (during performing the above
procedures) -> 0 V (until on-board
diagnostic activate verification buzzer
sounds)
Is voltage 0 V?
W 6 U 9 0 1 W E 7
Yes
Go to next step.
No
Visually check for bents or other damage to keyless unit
connector terminals.
Check for open or short circuit between keyless unit
terminal E and CPU connector terminal 2 0 .
13
Attempt to activate on-board diagnostic
function 1 or 2 again.
Does on-board diagnostic function 1 or 2
activate?
Yes
On-board diagnostic is operative now.
No
Replace keyless unit.
0 9 -0 1 E -1 3
Содержание MX-6 1998
Страница 1: ......
Страница 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Страница 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Страница 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Страница 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...
Страница 1005: ...TROUBLESHOOTING POWER DOOR LOCK SYSTEM From previous page Go to next page W 6 U 9 0 1 W H 3 09 01E 7...
Страница 1168: ...SEATS 4A 4 If not as specified replace the power seat switch 2A 2B t 4B 3A 1C 1A 1F W6U913WA9 09 13 7...