AUTOMATIC TRANSAXLE [LA4A-EL]
Transaxle fluid temperature (TFT)
1. Set an ohmmeter to the 1,000 ohm range.
2. Connect the positive lead to the + TFT jack.
3. Connect the negative lead to the - TFT jack.
W 6 U 5 1 7 W A 8
4. Record the resistace. Resistance will vary with
temperature.
5. Refer to the chart for the valves.
Tem perature “ C {°F }
R esistance k fì
-4 0 ------20 (-4 0 ------ 4)
967— 284
T—
C
O
I
i
T
I
C
D
T
284— 100
0— 20 {32— 68}
100— 37
2 1 - 4 0 {59— 104}
37— 16
41— 70 {105— 158}
16— 5
71— 9 0 (1 5 9 — 194}
5— 2.7
91— 110(195— 230}
2.7— 1.5
111— 130 {231— 266}
1.5— 0.8
131— 150 {267— 302}
0.8— 0.54
6. If out of range, refer to the Pinpoint test BA, BB,
BC, BD, BE, BF. (Refer to 0 5 -0 1 A AUTOMATIC
TRANSAXLE ON-BOARD DIAGNOSIS
[LA4A-EL].)
Turbine shaft speed (TSS) sensor
1. Set an ohmmeter to the 1,000 ohm range.
2. Connect the postive lead to the +TSS jack.
3. Connect the negative lead to the -T S S jack.
Solenoid voltage tests
Note
•
LED will turn “GREEN” when solenoid
activates and turn “OFF” when deactivated.
LED will turn “ RED” if an activated
solenoid/harness is shorted to BAT+. LED will
remain “OFF” if an activated solenoid/harness
is shorted to ground or no continuity.
© ■
STA TU S
1
2
3
4
— O I
STTEbfsi
| |
p tf
IfC TT
- o I "6
rsen
irsnroni OFF-irSET
W 6 U 5 1 7 W A D
1. Set Bench/Drive switch to “BENCH” mode.
2. Set an voltmeter to the 20 volt D.C. range.
3. Connect the voltmeter positive lead to the
appropriate solenoid power circuit.
4. Connect voltmeter negative lead to the
appropriate solenoid.
W 6 U 5 1 7 W A E
W 6 U 5 1 7 W A C
5. Using the voltmeter, check for voltage across
each solenoid by activating the solenoid switch.
Select the appropriate solenoid with the rotary
switch and depress the corresponding solenoid
switch. The “LED” should illuminate, the voltage
should change, and an audible click is heard. If
“ LED” does not illuminate, there is a short to
ground condition.
6. Observe and record the values.
Dynamic testing-engine “ON”
Dynamic testing is the final step in the transaxle tester
usage. It allows the transaxle to be proven out
electronically and hydraulically.
4. Record the resistance.
5. TSS should be
140— 290 ohm.
6. If out of range, refer to the Pinpoint test F.
(Refer to 0 5 -0 1 A AUTOMATIC TRANSAXLE
ON-BOARD DIAGNOSIS [LA4A-EL].)
0 5 -1 7A-11
Содержание MX-6 1998
Страница 1: ......
Страница 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Страница 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Страница 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Страница 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...
Страница 1005: ...TROUBLESHOOTING POWER DOOR LOCK SYSTEM From previous page Go to next page W 6 U 9 0 1 W H 3 09 01E 7...
Страница 1168: ...SEATS 4A 4 If not as specified replace the power seat switch 2A 2B t 4B 3A 1C 1A 1F W6U913WA9 09 13 7...