CONTROL SYSTEM
Terminal
Signal
Connection
Test condition
Voltage (V)/
Continuity
Inspection area
2B
GND
Air mix actuator
Constant: Check for continuity to
ground
Yes
—
2C
Motor drive
Air mix actuator
Moving to HOT
0.6
Air mix actuator
Moving to COLD
10.7
2D
Potentiometer
input
Air mix actuator
Airflow temperature mode at MAX
HOT
4.3
Air mix actuator
Airflow temperature mode at MAX
COLD
0.6
2F
Motor drive
Air mix actuator
Moving to COLD
0.6
Air mix actuator
Moving to HOT
10.7
2H
Motor drive
Airflow mode
actuator
Moving to VENT
10.6
Airflow mode actuator
Moving to DEFROSTER
0.7
2I
Motor drive
Airflow mode
actuator
Moving to DEFROSTER
10.6
Airflow mode actuator
Moving to VENT
0.7
2J
GND
GND
Constant: Check for continuity to
ground
Yes
—
2K
Power supply
ROOM 15 A
fuse
Constant
B+
ROOM 15 A fuse
2L
IG2
A/C 10 A fuse
IG SW at ON
B+
A/C 10 A fuse
IG SW at LOCK or ACC
0
FAN SWITCH REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Remove the heater control unit. (Refer to 07-40
HEATER CONTROL UNIT
REMOVAL/INSTALLATION.)
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
W 6 U 7 4 0 W A Z
W 6 U 7 4 0 W 2 1
1
Knob
2
Nut
3
Washer
4
Fan switch
0 7 -4 0 -1 5
Содержание MX-6 1998
Страница 1: ......
Страница 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Страница 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Страница 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Страница 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...
Страница 1005: ...TROUBLESHOOTING POWER DOOR LOCK SYSTEM From previous page Go to next page W 6 U 9 0 1 W H 3 09 01E 7...
Страница 1168: ...SEATS 4A 4 If not as specified replace the power seat switch 2A 2B t 4B 3A 1C 1A 1F W6U913WA9 09 13 7...