Power Management
13-128
Figure 13–45. Power Management Signal Values
Device not powered
not attached to USB
PUEN_O = 0
SUSPEND_O = 1
SHUTOFF_O = 1
DS_WAKE_REQ_ON = 1
Power on
No power
USB cable inserted
PUEN_O = 1
SUSPEND_O = 1
SHUTOFF_O = 1
DS_WAKE_REQ_ON = 1
PUEN_O = 0
SUSPEND_O = 1
SHUTOFF_O = 1
DS_WAKE_REQ_ON = 0
LH sets SYSCON1.
Pullup_En.
USB cable inserted
Power on
PUEN_O =1
SUSPEND_O = 1
SHUTOFF_O = 1
DS_WAKE_REQ_ON = 0
LH sets SYSCON1.
Pullup_En.
USB cable inserted
PUEN_O =1
SUSPEND_O = 0
SHUTOFF_O = 0
DS_WAKE_REQ_ON = 0
USB reset
PUEN_O =1
SUSPEND_O = 1
SHUTOFF_O = 1
DS_WAKE_REQ_ON = 1
(after DS_Chg interrupt
handling)
Idle for more
Reset or
resume
SHUTOFF_O value is 0 if the LH
has set SYSCON1.SOFF_D bit
SUSPEND_O value remains
1 until USB Reset is
effective (after 2,5
µ
s).
than 5 ms
†
†
†
†
†