ETM Environment
2-76
The ETM trace signals are multiplexed with the camera interface pins on the
OMAP5910 device. The default value upon reset is the camera interface.
Refer to Section 6.8, Configuration Module, and Section A.2, I/O Functional
Multiplexing, for details on pin multiplexing.
Figure 2–26. Trace Signals Multiplexing
Camera
interface
ETM 9
MPU
Agilent E5903A 301 TPA
or
16700A series logic analyzer
With E959A 002 TPA
trace_pipestat_[2:0]
trace_pkt_[7:0]
trace_sync
trace_clk
OMAP5910
Pin multiplexing logic