264
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PA07
CDV
(▲)
Electronic gear denominator
When setting E-Gear ratio, the incorrect setting may
cause servo motor suddenly unintended
acceleration. Ensure to do the setting when SERVO
is OFF.
Note: limitation : 1/50 < (CMX/CDV) < 64000
Pr,Pt
1
1
~
2
26
N/A
PA08
HSPD1
Homing high speed option 1
Pr
100
1
~
2000
Rpm
mm/s
PA09
HSPD2
Homing high speed option 2
Pr
20
1
~
500
Rpm
mm/s
PA10 RES1
(*)
Regenerative resistor value
Model
Default
value
below 500W
100Ω
750W~1KW
40Ω
1.5KW~3KW
13Ω
All
Refer to
the left
table.
10
~
750
Ohm