289
PB46 NHD4 Attenuation of machine resonance suppression
filter 4
This parameter is to set attenuation rate of
machine resonance suppression filter and it should
use together with NHF4.
Note: 0: turn off Notch filter function.
All
0
0
~
32
dB
PB47 NHF5 Frequency of machine resonance suppression
filter 5
This parameter is to set the frequency of machine
resonance suppression filter, its usage is same as
PB01.
All
1000
10
~
4000
Hz
PB48 NHD5 Attenuation of machine resonance suppression
filter 5
This parameter is to set attenuation rate of
machine resonance suppression filter and it should
use together with NHF5.
Note: 0: turn off Notch filter function.
All
0
0
~
32
dB
PB49 DOB External interference compensation gain
In position mode, increasing this parameter setting
value can reduce position overshoot.
In speed mode, increasing this parameter setting
value can reduce speed overshoot
Note: if the parameter setting is too large, it might
cause system vibration.
All
0
0
~
100
N/A
PB50 MVF Position command average filter time constant
0: disable
1~50: enable the filter function
Pr,
Pt
0
0
~
50
ms
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...