169
Positioning
moving distance
if the load cause resonance
set PB29=1
if the vibrate is reduced
Finish
If both PB32 and
PB34=1
Decrease PB30
Increase PB30
6.3.7.
Gain switch function
Shihlin servo drive provides gain switching function. It can switch the gain on the operating or
stopped servo motor. The switching can be performed by DI pins which are set to switch. If
the users want to apply gain switching options, manual mode is required( PA02 is set to □□□0
or □□□1). If the auto-gain switching mode is applied, the gain switching function will be
disabled.
It is applicable in below occasions:
(1).
Servo gain setting is too large and makes big noise, you can use the gain switching
function to reduce the system gain.