283
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PB20 SJIT Speed feedback filter time constant
This parameter is to set speed feedback filter time
constant.
All
0
0
~
1000
0.1ms
PB21
NHF2 Frequency of machine resonance suppression
filter 2
This parameter is to set the frequency of machine
resonance suppression filter, and the usage is
same as PB01.
All
1000
10
~
4000
Hz
PB22
NHD2 Attenuation of machine resonance suppression
filter 2
This parameter is to set the attenuation rate of
machine resonance suppression filter and it
should use together with NHF2.
Note: 0: turn off Notch filter function
All
0
0
~
32
dB
PB23
Reserved
All
0
0~1
N/A
PB24
VDC Speed differential compensation
This parameter is to set speed differential
compensation, it’s valid when DI terminal
proportional control signal is ON.
Pr,
Pt,
S
980
0
~
1000
N/A
PB25 NHF3 Frequency of machine resonance suppression
filter 3
This parameter is to set the frequency of machine
resonance suppression filter, its usage is the same
as PB01.
All
1000
10
~
4000
Hz
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...