198
is set to -500, the analog voltage of MOD can be corrected to the same value as the actual
voltage. If the analog voltage of MOD is smaller than the actual voltage, please input a positive
value in PC28 or PC29.
Analog monitor output ratio
The analog monitor output ratio is used to set the resolution of the analog monitor voltage
output. The relevant parameters are as follows:
Name
Parameter
abbreviation
Parameter
code
Setting
range
Description
Unit
Default
value
Control
mode
MON1
analog
monitor
output
ratio
MOG1
PC30
1~100
Set the
maximum
ratio of analog
monitor 1
output
%
100
ALL
MON2
analog
monitor
output
ratio
MOG2
PC31
1~100
Set the
maximum
ratio of analog
monitor 2
output
%
100
ALL
Assuming that the rated speed of the motor is ±3000 rpm, and the current speed of the motor
is +3000 rpm, the voltage observed by the MON should be +5V. If MOG1 or MOG2 is set to
50%, the analog voltage observed by the MON will 10V.
MOD output voltage= current monitoring value/ maximum monitoring value * 10V / MOG.
The unit of MOG1 and MOG2 are %.
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...