423
0x0106
The 6th alarm in the past
1word
0x0107
The 7th alarm in the past
1word
0x0108
The 8th alarm in the past
1word
0x0109
The 9th alarm in the past
1word
0x010A
The 10th alarm in the past
1word
0x010B
Alarm
occurrence
time(low word)(PG05)
1word
0x010C
Alarm occurrence time(high word)(PG06)
1word
0x010D
1st alarm record occurrence time(low word)(PG07)
1word
0x010E
1st alarm record occurrence time(high word) (PG08)
1word
0x010F
2nd alarm record occurrence time(low word) (PG09)
1word
0x0110
2nd alarm record occurrence time(high word)(PG10)
1word
0x0111
3rd alarm record occurrence time(low word)(PG11)
1word
0x0112
3rd alarm record occurrence time(high word)(PG12)
1word
0x0113
4th alarm record occurrence time(low word)(PG13)
1word
0x0114
4th alarm record occurrence time(high word)(PG14)
1word
0x0115
5th alarm record occurrence time(low word)(PG15)
1word
0x0116
5th alarm record occurrence time(high word)(PG16)
1word
0x0117
6th alarm record occurrence time(low word)
1word
0x0118
6th alarm record occurrence time(high word)
1word
0x0119
7th alarm record occurrence time(low word)
1word
0x011A
7th alarm record occurrence time(high word)
1word
0x011B
8th alarm record occurrence time(low word)
1word
0x011C
8th alarm record occurrence time(high word)
1word
0x011D
9th alarm record occurrence time(low word)
1word
0x011E
9th alarm record occurrence time(high word)
1word
Note: returning 0x00ff means no alarm, returning 0x0001 means AL.01 occurs, returning
0x0012 means AL.12 occurs, and so on.
(4) Alarm data clearance (readable and writable)
Communication
address
Content
Data
length
0x0130
If “0x1EA5” is written to this address, it will clear current
alarm.
When reading this address, it will return current alarm.
The setting range is 0~0xFFFF.
1word
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...