386
No.
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PL08
Hall sensor offset angle:
When the Hall sensor makes hysteresis due to
different motion directions of the motor, the U phase
zero point of the Hall sensor will be based on the
central angle of the hysteresis.
(For the description of hysteresis, refer to the
diagram of PL09).
All
0
0 ~
3600
0.1°
(Electr
ical
angle)
PL09
Hall sensor hysteresis width:
Hysteresis width is as follows:
All
0
0 ~
3600
0.1°
(Electr
ical
angle)