343
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PC89
SPF1
z: reserved
u: reverse inhibit
PC89.u = 0: disabled.
PC89.u = 1: enabled.
When this function is enabled, the reverse
command is inhibited and saved inside. When the
value of forward rotation exceeds this reverse
value, the forward command output is generated.
PR command (pulse)
PR command (pulse)
time (sec)
time (sec)
Reverse command
Pr
0000h
0000h
~
107Fh
N/A