358
PD31 OTST
(■)
DO communication control contact status(HEX):
If DO is controlled by parameter, PD31 can
determine DO contact status(6 contacts). Bit0~Bit5
corresponds to DO1~DO6.
0=DO contact is off.
1=DO contact is on.
Note, you can refer to PD25 setting.
Turret
mode
0000h
0000h
~
003Fh
N/A
PD32
SDLY
(*)
Servo ON delay time when SON is ON.
This parameter is to set the delay time of SERVO ON
when the SON is ON.
All
0
0
~
3000
msec
PD33 SFDO Software DO register
The bit0 ~ bit7 of this parameter setting controls DO
signal S_DO0 ~ S_DO7 separately.
All 0000h
0000h
~
00FFh
N/A