160
(Note) DI signal
Valid torque limit value
TL1
TL
0
0
PA05 setting
0
1
TLA > PA05 setting => PA05 setting
TLA < PA05 setting => TLA
1
0
PC25 setting > PA05 setting => PA05 setting
PC25 setting < PA05 setting => PC25 setting
1
1
TLA > PC25 setting => PC25 setting
TLA < PC25 setting => TLA
Note 0: OFF(TLx-SG is open-circuited) 1: ON (TLx-SG is short-circuited)
When the generated torque of the servo motor reaches the torque limit value setting by the
PA05, PC 25 or the analog torque limit, TLC -SG will be conductive and TLC is digital output.
Name
Parameter
abbreviation
Description
Control
mode
Torque
limiting
control
TLC
When the generated torque reaches the torque
value setting by the Inner torque limit 1(PA05) or the
analog torque limit(TLA), TLC -SG will be
conductive. TLC-SG will not be conductive when
SON is off.