211
The definition of OPT option is as follows:
OPT option
Bit 7
(0/8)
Bit 6
(0/4)
Bit 5
(0/2)
Bit 4
(0/1)
x
ROM
( Write in ROM)
AUTO
(Automatic execution)
INS
(Interrupt)
INS:
if set to INS, it means the current PR will interrupt the previous PR.
AUTO:
execute the next PR path automatically when the current PR is completed.
ROM:
when BIT6=0, it means the parameter will not write to EEPROM, when Bit 6=1, it means
the parameter will write to EEPROM in the meantime.
Target writing parameter: the group and number of the writing parameter can be set.
Target writing parameter
Bit 16~19
Bit 12~15
Bit 11~8
Parameter
group
A→1
B→2
C→3
D→4
E→5
F→6
Parameter number(Decimal)
P□05→05
P□45→45
P□98→98
P□77→77
(For example: if the writing target parameter is PF34, you can set to 634)
DLY: the value range is 0~F, it can be set as delay time number, and its definition is as follows:
DLY value
F
E
D
C
B
…
4
3
2
1
0
Corresponding
parameters
PF80 PF79 PF78 PF77 PF76 … PF69 PF68 PF67 PF66 PF65