346
No. Abbr.
Parameter function and description
Mode Default Range Unit
PD01
DIA1
(*)
Input signal automatic ON option
u (EMG)
z (LSN)
y (LSP)
x (SON)
x=0: the open/short status of SON-SG is controlled
by the external circuit of the drive.
x=1: SON-SG is auto short-circuited internally
without external wiring.
y=0: the open/short status of LSP-SG is controlled by
the external circuit of the drive.
y=1: LSP-SG is auto short-circuited internally without
external wiring.
z=0: the open/short status of LSN-SG is controlled by
the external circuit of the drive.
z=1: LSN-SG is auto short-circuited internally without
external wiring.
u=0: the open/short status of EMG-SG is controlled
by the external circuit of the drive.
u=1: EMG-SG is short-circuited internally without
external wiring.
All 0000h
0000h
~
1111h
N/A
PD02
DI1
(*)
Input signal option 1:
To define the function of CN1-14 pin input signal.
In different control modes, the input signals are not
exactly the same. The user can define CN1-14 input
signal in different control mode by setting PD02.
All 0001h
0000h
~
002Fh
N/A
PD03
DI2
(*)
Input signal option 2
To define the function of CN1-15 pin input signal.
CN1-15 can be assigned for any input signal, its
parameter setting is same as PD02, you can refer to
PD02 setting description.
All 000Dh
0000h
~
002Fh
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...