512
13.2 Delta absolute position detection system
This section mainly introduces the use of Delta PLC with SDP servo to read absolute position
by DIO communication.
13.2.1
Signal description
When transmitting absolute position data, the signal of CN1 terminal will be changed.
Signal
Code
CN1 Pin
Function
I/O
ABS
communication
enabled
ABSE User-defined
When ABSE is on, the ABS mode is
activated, it will enable ABSQ, ABSC,
ABSR, ABSD.
DI-x
ABS signal
request
ABSQ
17
Handshake communication check pin
during I/O transmission, ABSQ OFF
means the controller has issued the
requested command; ABSQ ON means
the controller has processed the ABSD
data.
DI-4
(Fixed)
ABS signal
ready
ABSR
43
ABSR OFF means that ABSQ command
can be received; ABSR ON means that the
data is ready and the ABSD data has been
updated.
DO-3
(Fixed)
ABS data
content
ABSD
44
The output pin of ABS data, the data is
guaranteed to be correct when ABSR is
on.
DO-4
(Fixed)
ABS
communication
error
ABSW User-defined
The related alarm of the absolute encoder
is indicated by this DO output.
DO-x
Origin setting
ABSC User-defined
When ABSC is turned on, the pulse
number in the absolute encoder will be
cleared to zero. This input is valid only
when ABSE is turned on.
DI-x
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...