342
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PC89 SPF1 PR special filter setting:
u z y x
yx: the acceleration time limit
PC89.yx = 00: invalid
PC89.yx = 1~7F: acceleration time limit: yx *
10[ms]
With acceleration time limit(0~1270 ms), if the PR(E-
Cam) command changes too drastically, it will cause
mechanical vibration and jeopardize the production.
This
function
can
control
the
acceleration/deceleration within the limit in any time,
smooth the operation, reduce the noise and extend
the lifetime.
This function is different from the general filter: the
traditional filter works regardless the change of
command, which may cause command lag and
reduce system efficiency.
This function only filter when command change
exceeds the limitation. When the variation value is
small, the filter is invalid and no lag occurs. The
definition of this acceleration time is the motor
acceleration time from 0 to 3000rpm. Increasing time
will improve the effectiveness of filter, and also
improve the stability of the acceleration /deceleration
operation.
Pr 0000h
0000h
~
107Fh
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...