217
Sequential command(AUTO):
use the AUTO function to generate a fixed sequence of
program command combinations.
PATH#12 (AUTO positioning control, incremental positioning path: 104857600 pulse, delay
time: 200ms) → PATH#13(Positioning control, absolute positioning: 0 pulse).
As shown in the figure below, which is a typical sequential command of positioning control
followed by positioning control. In positioning control, the delay time starts counting after the
positioning is completed.
PATH#12(AUTO speed control, target speed: 2000 rpm, delay time: 200ms) → PATH#13
(Positioning control, absolute positioning: 0 pulse)
As shown in the figure below, it is a typical sequential command of speed control followed by
positioning control. In speed control, the delay time will start counting after the positioning is
completed.