179
Pulse logic and format
Forward rotation
Reverse rotation
Neg
a
tive
lo
g
ic
AB phase pulse train
Pulse train + sign
Forward/reverse rotation
pulse train
P
o
sitive
lo
g
ic
AB phase pulse train
Pulse train+ sign
Forward/reverse rotation
pulse train
If input pulse is line drive type, the maximum frequency is 4Mpps. If input pulse is open
collector type, the maximum frequency is 200Kpps.
6.4.2 Internal position command (Pr command)
◆
You can refer to detail in chapter 7.
The source of the PR position command is to use 64 groups built-in position command register
of parameters(PE01~PE98), (PF01~PF30), together with external I/O( CN1, POS1 ~ POS6
and CTRG)to select one as position command, the detail shows in the following table.