504
(2)
Transmission method
In the absolute position detection system, when SON is turned on, ABSM must be turned on to
transmit the current position of the drive to the host controller. If ABSM is turn off, the main
power circuit will be off.
(a)Timing diagram
(1)
After the ABS data transmission is completed, RD turns on and ABSM is OFF. When
RD is on, ABSM can not be turned on.
(2)
Even if SON is turned on, the main circuit will not be switched on until the ABSM is
turned on. When an alarm occurs, ABSM can not be enabled; when a warning occurs,
ABSM can be enabled.
(3)
During ABS transmission, if ABSM is OFF, the ABS transmission mode is interrupted
and [AL.17 ABS timeout warning] occurs.
During ABS transmission, [AL.17 ABS timeout warning] will also occur when SON OFF,
RES ON or EMG OFF.