253
Filter smoothing and resonance suppression relevant parameters
Parameter
NO#
Abbreviation
Parameter function
Default
value
Unit
Control
mode
Pt Pr S T
PB01
NHF1
Frequency of machine resonance
suppression filter 1
1000
Hz
○ ○ ○ ○
PB02
NHD1
Attenuation rate of machine
resonance suppression filter 1
0
dB
○ ○ ○ ○
PB03
NLP
Resonance suppression low-pass
filter
10
0.1ms ○ ○ ○ ○
PB04
PST
Position command filter time
constant
3
ms
○ ○
PB19
TQC
Torque command filter time constant
0
ms
○
PB20
SJIT
Speed feedback filter time constant
0
0.1ms ○ ○ ○ ○
PB21
NHF2
Frequency of machine resonance
suppression filter 2
1000
Hz
○ ○ ○ ○
PB22
NHD2
Attenuation of machine resonance
suppression filter 2
0
dB
○ ○ ○ ○
PB23(▲)
IGE
Current gain enhancement function
0
N/A ○ ○ ○ ○
PB25
NHF3
Frequency of machine resonance
suppression filter 3
1000
Hz ○ ○ ○ ○
PB26
NHD3
Attenuation of machine resonance
suppression filter 3
0
dB ○ ○ ○ ○
PB27
ANCF
Auto resonance suppression mode
setting
1
N/A ○ ○ ○ ○
PB28
ANCL
Auto resonance suppression
detection level
50
%
○ ○ ○ ○
PB29
AVSM
Auto low frequency vibration
suppression mode setting
0
N/A ○ ○
PB30
VCL
Low-frequency vibration detection
level setting
50
pulse ○ ○
PB31
VSF1
Low-frequency vibration
suppression frequency setting 1
100
0.1Hz ○ ○
PB32
VSG1
Low-frequency vibration
suppression gain 1
0
N/A ○ ○
PB33
VSF2
Low-frequency vibration
suppression frequency setting 2
100
0.1Hz ○ ○
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...