129
should be the 10% or more of rated
torque.
Load inertia estimation
failure or inertia ratio
change enormously due
to resonance.
Adjust to semi-auto gain tuning mode, in
which the motor will stop load inertia
estimation, and then execute one-touch
tuning again.
Select [PA02_ATUM]
Set[PB06_GD1] to manually set load
inertia ratio.
C00F
One-touch
tuning function
invalid
In [PA38_AOP3] setting,
the one-touch tuning
function is disabled.
Set [PA38_AOP3]