6.4.1 External pulse command(Pt command)
The pulse command (Pt command) is provided by an external device. You should set PA01 to
0000 and then restart power to activate this parameter. There are three types of user-defined
input waveform. each type can be defined positive and negative logic. Positive logic means
the pulse is triggered by the rising edge, on the other hand, negative logic means the pulse is
triggered by the falling edge. The related parameters and setting methods are as follows:
Name
Abbr. Code Range Unit
Defa
ult
Mod
e
Description
Function
mode
option 3
(comma
nd pulse
option)
PLSS PA13
0000h
~
0312h
N/A
0000
h
Pt
Set external input pulse train type
0 z y x
x: input pulse train format options
x=0:forward/reverse rotation pulse
train
x=1: pulse train+sign
x=2: AB phase pulse train.
y: input pulse-train logic options
y=0: positive logic
y=1: negative logic
z: The setting of input pulse filter.
z=0: the maximum input pulse
frequency is 500kpps.
(applicable frequency is between
200kpps-500kpps)
z=1: the maximum input pulse
frequency is 200kpps.
(applicable frequency is below
200kpps)
z=2: the maximum input pulse
frequency is 2Mpps.
(applicable frequency is between
500kpps ~2Mpps)
z=3: the maximum input pulse
frequency is 4Mpps.
(applicable frequency is between
2MPPS~4MPPS)
This parameter setting is valid after power cycling.
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...