KR
-
A535M Driver inner circuit
>
※
The above specifications are changeable at anytime without notice.
(Unit:mm)
Switch No
Current
(A/Phase)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0.4 0.5 0.57 0.63 0.71 0.77 0.84 0.9 0.96 1.02 1.09 1.15 1.22 1.27 1.33 1.4
1 step angle of 5-phase stepping motor =
Basic step angle(0.72°)
Resolution
Motor Driver(5-Phase microstepping driver)
KR-A535M
Thank you very much for selecting Technodrive products.
For your safety, please read the following before using.
M A N U A L
※
Please keep these instructions and review them before using this unit.
※
Please observe the cautions that follow ;
Serious injury may result if instructions are not followed.
Product may be damaged, or injury may result if instructions are not followed.
※
The following is an explanation of the symbols used in the operation manual.
caution:Injury or danger may occur under special conditions.
Warning
Caution
Warning
Caution
In case of using this unit with machinery(Nuclear power control, medical equipment, vehicle,
train, airplane, combustion apparatus, entertainment or safety device etc), it is required to
install fail-safe device, or contact us for information on type required.
It may cause serious human injury or a fire, property.
Installation, connection, operation, control, maintenance should be carried out by person
who has been qualified.
It may cause a fire, human injury or give an electric shock.
It should be installed and earth independently and grounding wire should be over than AWG
No.18(0.75mm
2
).
It may give an electric shock.
Please install this unit after consider countplan against power failure.
It may cause human injury or damage to product by releasing holding torque of motor.
Do not use this unit outdoors or place where there are explosiveness, flammable, corrosive
gas, water and frequent vibration etc.
It may cause a fire or give an electric shock.
Do no touch this unit or connection terminal of condenser within 30sec after turn off the power.
It may give an electric shock by residual voltage.
Do not put finger or any object in to this product.
It may cause a fire or give an electric shock.
Do not disassemble or modify this unit. Please contact us if it required.
It may cause a fire, give an electric shock or damage to product.
Please adjust the volume switch with insulated screw driver.
It may give an electric shock.
It should be insulated not to expose the conductor, because connecting party has a
dangerous voltage when join to connector.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Do not move, install or maintain during it is operating.
It may give an electric shock.
Power input voltage must be used within rating specification and power line should be over
than AWG NO. 18(0.75mm
2
).
It may cause a fire or give an electric shock.
Please check the connection before power.
It may cause a fire or give an electric shock.
When you connect to power, please install current breaker.
It may cause a fire.
Please turn off when power failure occurred.
It may cause human injury or damage to product due to sudden movement by recovering from
power failure.
Do not touch during the operation or after a while of operation.
It may cause a burn due to high temperature in surface.
The emergency stop should be enabled during the operation.
It may cause human injury or damage to product.
Please apply power after checking control input signal.
It may cause human injury or damage to product by sudden movement.
Do not turn on the HOLD OFF signal input while it is maintaining vertical position.
It may cause human injury or damage to product by releasing holding torque of motor.
Please install a safety device when need to remain the vertical position after turn off the
power.
It may cause human injury or damage to product by releasing holding torque of motor.
Please check if HOLD OFF signal input is ON when need to set the output manually.
It may cause human injury by sudden movement.
Please stop this unit when mechanical problem is occurred.
It may cause a fire or human injury.
Do not touch the terminal when during the insulation dielectric strength test or insulation
resistance measurement.
It may give an electric shock.
Please observe rating specification.
It may cause a fire, give an electric shock or damage to product.
In cleaning the unit, do not use water or an oil-based detergent.
It may cause a fire or give an electric shock.
Please separate as industrial waste when disuse this unit.
Use the specified 5-phase stepping motor in motor output terminal.
It may cause a fire or damage to product.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
CW Pulse
ON
OFF
CCW Pulse
ZERO OUT
ON
OFF
ON
OFF
0 1 2 3 4 5 6 7 8 9 0 1 1 0
CW
CCW
Rotation
position
CW
CCW
CW
CCW
Rotation
position
CW
CCW
No
1
2
Function
Self diagnosis function
Pulse input method
ON
250pps rotation
Normal
1 Pulse input
3
Auto Current Down
OFF
2 Pulse input
Use
No use
Name
TEST
2/1 CLK
C/D
ON 1 2 3
Switch position
2 Pulse type
1 Pulse type
TEST
2/1 CLK
CW / CCW Input(CW : Clockwise direction from the front view of shaft)
ZERO OUT output
Selectable function switch
Setting RUN current
Add external resistor when power
for pulse from the external of the
unit e5VDC.
1
Motor excitation OFF control signal
[H] Motor excitation OFF
2 Pulse input method(reverse rotation signal input)
1 Pulse input method(rotating direction signal input)
[H] : CW, [L] : CCW
2 Pulse input method(forward rotation signal input)
1 Pulse input method(pulse signal input)
CCW
CW
Division(MS1, MS2) selection signal
[L] : Operated by switch MS1
[H] : Operated by switch MS2
Zero point excitation output signal
ON for zero point excitation
6
2
3
4
5
7
8
9
10
HOLD OFF
DIVISION
SELECTION
ZERO OUT
270
Ω
270
Ω
390
Ω
390
Ω
10
Ω
Blue
Red
Orange
Green
Black
1
2
3
4
5
Motor
Blue / Black
10
L
e
a
d
w
i
r
e
s
Red / Brown
Orange / Purple
Green / Yellow
White / Gray
F.G
100-220VAC
50/60Hz
AC
AC
F.G
L
N
Note)
[Signal]
I/O terminal connection diagram
[Motor]
[Power]
Motor connection diagram and power supply
It rotates at a speed of 250pps in Full Step and it is changed depending on resolution.
It rotates to CCW in 1 Pulse input method and CW in 2 Pulse input method.
※
※
CURRENT DOWN
It is to reduce RUN current according to the setting rate of STOP current switch when motor
stops in order to reduce motor’s heat generation.
Current is reduced from approx.500[ms] after the last pulse input.
※
※
Switch No
%
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
27
31
36
40
45
50
54
58
62
66
70
74
78
82
86
90
Setting STOP current
Zero point excitation output signal(ZERO OUT)
RUN current is phase current for 5 phase stepping motor.
There can be an error in RUN current setting value by driving frequency.
RUN current should be used within the rated current of motor, or it may cause overheating,
step-out and loss of torque.
STOP current is phase current provided to 5-phase of stepping motor to be stopped.
The switch setting value of STOP current is a percentage of RUN current switch setting current
value.
There can be an error in STOP current by coil impedance of motor.
This function shall be operated when CURRENT DOWN switch is set to OFF. In case CURRENT
DOWN switch is set to ON, RUN CURRENT shall be provided both when a motor stops and
when a motor runs.
It indicates the initial step of excitation status of stepping motor and rotation position of motor
axis from previously set zero.
HOLD OFF function
HOLD OFF is [H], the excitation is released, because current provided to each phase is cut off.
HOLD OFF is [L], the excitation is in a normal status.
It rotates motor axis by external force or is used for manual positioning.
Input H/L means ON/OFF of photocoupler in a circuit.
Switch No
Resolution
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
4
5
8
10
16
20
25
40
50
80 100 125 200 250
Setting micro step(Microstep:Resolution)
Alarm function
Setting resolution(Same for MS1, MS2)
Overheat
Overcurrent
It drives a motor dividing basic step angle(0.72°) by setting value of resolution.
※
Selectable resolution(Selectable Step angle)
Change into the resolution in MS1/MS2 by DIVISION SELECTION input.
Motor is rotated by resolution in MS1 when DIVISION SELECTION signal is [L] and MS2 for [H].
Change the resolution after motor is stopped or, it may cause a step-out of motor.
Input H/L means ON/OFF of photocoupler in a circuit.
※
※
※
※
When base temperature of driver is over 80
℃
, alarm LED(Red) is lighted and motor will be stop
holding the excitation. Reset the power after remove the existing factors of overheat that can
be occurred to release the Alarm.
When overcurrent is applied from breakdown or error to the motor, alarm LED (Red) is Flickered.
In case overcurrent occurs, a motor will become HOLD OFF. A driver will resume its normal
operation when error causing factors are disappeared.
When resolution is changed during the operation of motor, it may cause a step-out of motor.
※
CW+
CW
-
CCW+
CCW
-
Hold Of
f+
Hold Of
f-
Division Se
Division Selection-
Zero Out+
Zero Out-
Blue
Red
Orange
Green
Black
100-220VAC
50/60Hz
L
N
F.G
※
It may cause malfunction if above instructions are not followed.
1. If motor does not rotate
①
Check the connection status of controller and driver and pulse input specification. (Voltage,
width)
②
Check the input pulse method and connected method is same.
③
Check pulse and direction signal is connected correctly for 1 pulse input method.
3. If motor does not work properly
①
Check the connection of driver and motor.
②
Check the pulse input specification of driver. (Voltage, width)
③
Check output current for current adjuster and current for motor operation as correct.
④
After turning off the power, wait at least 15 seconds before turning the power back on.
2. If motor rotates as a reverse direction
①
Check input pulse connection of CW and CCW is correct for 2 pulse input method.
②
In case of 1-pulse method, it is forward rotation when CCW input is [H] and reverse rotation
when CCW input is [L].
ZERO OUT means the initial status of motor excitation (STEP 0), it outputs per 7.2° of rotation
in Full Step. (It outputs 50times per 1 rotation of motor.)
Ex) Full step : It outputs one time when input 10 pulse.
20 division : It outputs one time when input 200 pulse.
※
Pulse input method selection
1 Pulse method : Input pulse signal input in CW and rotating direction signal in CCW.
It rotates to CCW when [L] and CW for [H].
2 Pulse method : Motor is rotated to CW when input pulse in CW and to CCW when input
pulse in CCW.
※
※
※
101, New Well Ikuta Bldg.,
26-28, Mita 1-chome, Tama-ku, Kawasaki-shi, Kanagawa Pref., 214-0034, Japan
TEL. +81-44-935-0072 FAX. +81-44-935-0708
URL. http://www.technodrive.com
E-Mail. [email protected]
120
170
5
122
134.3
4-M4 TAP Dp:8
108
7
156
5
40
42
20
EP-JE-14-0009B
※
(1) Ambient temperature is 25
℃
and ambient humidity is 55%RH.
※
(2) The max. value of RUN current is based on RMS value in accordance with frequency of
running motor, peak power can be changed by load fluctuation.
※
(3) Variable depending on resolution and motor's load.
CW/
CCW
Input
pulse
1, 2, 4, 5, 8, 10, 16, 20, 25, 40, 50, 80, 100, 125, 200, 250 division
Model
KR
-
A535M
Unit weight
Power supply
RUN current (2)
Ambient temperature
100
-
220VAC
±
10% 50/60Hz
0.4~1.4A/Phase
0~50
℃
(at non-freezing status)
Approx. 660g
Ambient humidity
35~85%RH(at non-dew status)
Power consumption (1)
Resolution
Pulse width
Pulse interval
Rising/falling time
Voltage
Frequency(3)
3A(Max.)
Min. 0.25
㎲
(Duty max. 50%)
Min. 0.25
㎲
(Duty max. 50%)
Max. 1
㎲
Max. 500kpps
High
:
4
-
8VDC
,
Low
:
0
-
0.5VDC
Current
10~20mA
Drive method
Bipolar constant current pentagon drive
Specification
Caution for your safety
Input
・
Output diagram
Function
Failure diagnosis and management
Caution for using
Dimensions
Time charts
Connections
③
Pollution Degree 2
④
Installation Category
Ⅱ
①
It shall be used indoor
②
Altitude Max. 2000m
3. Caution for wiring
①
Use Twist pair(Over 0.2mm
2
) for the signal wire should be shorter than 2m.
②
Please use an electric wire is thicker than the motor lead when product the motor wire
connection.
③
Please leave a space over 10cm between a signal wire connection and power wire.
4. Caution for installation
①
②
Excessive heat generation may occur on Driver. Keep the heat sink under 80
℃
when installing
the unit.(In case it is over 80
℃
, forcible cooling shall be required.)
In order to increase heat protection efficiency, keep the heat sink as close as possible to
metal panel and keep it well-ventilated.
5. Caution for using function switches
6. Installation environment
①
Check the position of self-diagnosis switch before turn on the power.
It may be dangerous if turn on the power in [ON] status, due to motor is worked instantly or
cause a malfunction.
②
When the selection switch of input signal method is changed to 2 Pulse input method during
the operation with 1 Pulse input method, it may be danger as the revolution way of the motor
is changed conversely.
Please do not change the input signal method during the operation.
1. Caution for signal input
①
Do not input CW, CCW signal at the same time in 2 Pulse input method. It may not work
properly if another signal is supplied when one of them is ON.
②
In case, the signal input supply is higher than rated supply expressed on the specification,
please connect the additional resistor to external part.
2. Caution for supplying power
①
Use the power enough to supply the run current when turn on the power.
②
The current value indicated on power supply is the max. input of driver.