No Abbr.
Parameter function and description
Mode Default Range Unit
PC45 CPRS
Capture: reset position after first data captured
Please refer to PC44x. Bit1 description.
Note: pay attention to upper limit of the maximum
and minimum values when setting this parameter.
All
0
-
10737
41823
~
10737
41823
Source
pulse
PC46
CPMK Capture: masking range
When capturing multiple points (PC43>1), once one
data is captured, the system stops(masking) range
definition is as follows.
(the last capture data source position ± PC46 is set
as masking area)
All
0
0
~
1000
000
Source
pulse
PC47 CMST Compare: start address of data array:
The first data to be compared is saved at start
address in the data array.
Note: this parameter is only writable when CMP
turned off(PC50x.Bit = 0).
All
0
0
~
799
N/A
PC48 CMAX
(■)
Compare: axis position:
This parameter displays the axis position of the
CMP pulse source.
Note1: this parameter is only writable when CMP
stops (PC50 x.Bit = 0).
Note 2: this parameter is write-protected when the
axis source of Compare is the Capture axis(PC50 y
= 0).
Note3: when the axis source of Compare is main
encoder(PC50 Y=2), this parameter is also write-
protected. When you set PC50 Y=2, this parameter
is reset to the feedback position of the motor. When
the motor feedback position is redefined due to
homing or Capture, the value will be different from
All
0
-2
31
+1
~
2
31
-1
Source
pulse
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...