No Abbr.
Parameter function and description
Mode Default Range Unit
PA36 FNO2
(*)
Function option 2(reserved for factory test only)
All
0000h
0000h
~
FFFFh
N/A
PA37 FNO3
(*)
Function option 3(reserved for factory test only)
PA38 AOP3 One-touch tuning function option.
0 z y x
x: auto gain tuning function
x=0: disabled.
x=1: enabled.
y:
automatic
high-frequency
resonance
suppression function
y=0: disabled
y=1: enabled
z: auto low-frequency swing arm suppression
function
z=0: disabled
z=1: enabled
Note 1: x=1 is necessary condition to enable one
touch tuning function before you can set high-
frequency or low-frequency suppression function
Note 2: when y=1 and one-touch tuning is
completed, you must set PB27 to 0.
Note 3: when z=1 and one-touch tuning is
completed, you must set PB29 to 0.
Pr,
Pt,
S
0000h
0000h
~
0111h
N/A