291
PB55 NHW5 Width of machine resonance suppression filter 5:
This parameter is to set the 5th group of machine
resonance suppression filter width.
Note1: if PB47=0, this function is disabled.
Note2: PB46, PB47 and PB55 are 5th group of
machine resonance suppression filter related
parameters.
All
5
1
~
10
N/A
PB56
Reserved
PB57 TOF
(*)
z-axis torque compensation
When used in Z-axis applications, the torque
command can be compensated.
Note: improper settings may cause system
instability
All
0
-3000
~
3000
0.1%
PB58 VSD1 Attenuation of Low-frequency suppression 1
This parameter is to set the first group of low-
frequency suppression attenuation rate.
Note 1: if PB32=0, this function is disabled.
Note 2: PB31, PB32 and PB58 are first group of
low
frequency
suppression
filter
related
parameters.
Pr,
Pt
80
0
~
1000
dB
PB59 VSD2 Attenuation of Low-frequency suppression 2
This parameter is to set 2nd group of low
frequency suppression attenuation rate.
Note 1: if PB34=0, this function is disabled.
Note 2: PB33, PB34 and PB59 are 2nd group low
frequency suppression filter related parameters.
Pr,
Pt
80
0
~
1000
dB
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...