437
AL.0A Serial communication timeout
Alarm cause
Checking method
Corrective action
Servo drive has not received the
communication message for a
long time
Check if the
communication cable is
broken or loose.
Replace the cable or
reconnect the wiring.
Improper parameter setting for
PC23.
Check the setting value of
PC23.
Correctly set the
value of PC23.
AL.0B Encoder error 1
Alarm cause
Checking method
Corrective action
Encoder wiring is
incorrect.
Check if the wiring follows the
instructions in the user manual.
Wiring correctly.
Encoder connector is
loose.
Check the connection.
Re-install.
Encoder is damaged. Check if the motor is abnormal.
Replace the motor.
Encoder wiring is
poor.
Check if there is any poor wiring. Reconnect the wiring.
AL.0D
Fan error
Alarm cause
Checking method
Corrective action
Fan stops working.
Turn off the power, replace the fan by yourself, or send your
servo drive back to the distributor or manufacturer.
AL.0E IGBT overheat
Alarm cause
Checking method
Corrective action
The load is continuously over the
rated value or the drive output is
short-circuited.
Check if servo drive is
overloaded or motor is
over-current.
Check the drive output
wiring.
Reducing the load, or
replace the drive with a
larger capacity.
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...