285
PB30
VCL Low-frequency vibration detection level setting.
When
automatic
low-frequency
vibration
suppression is enabled (PB29=1), the system will
search automatically. Decreasing the PB30 setting
value will increase the detection sensitivity, but it
is easy to misjudge noise or other non-main low-
frequency vibration as vibration suppression
frequencies.
Increasing this value will decrease detection
sensitivity. However, if the vibration amplitude of
the mechanism is small, it is not easy to search for
low frequency vibration.
Pr,
Pt
50
1
~
8000
pulse
PB31 VSF1 Low-frequency vibration suppression frequency
setting 1
To set the frequency 1 of low-frequency vibration
suppression.
Note: when PB31 is 0, it means the 1st group of
low-frequency vibration suppression filter is off.
Pr,
Pt
100
1
~
3000
0.1Hz
PB32
VSG1 Low-frequency vibration suppression gain 1
To set the first group of low-frequency vibration
suppression gain. Increasing the value can
improve the position response, but if the setting
value is too large, it will jeopardize the motor to run
smoothly. So it is recommended to set to 1.
Pr,
Pt
0
0
~
15
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...