288
No Abbr.
Parameter function and description
Mode Default Range Unit
PB42 SBW
(▲)
Synchronous control bandwidth:
If you are unsure about PB39~PB41 setting, set
the value of synchronous control bandwidth
instead so that the value corresponds to
PB39~PB41.
When the deviation between the synchronous
control bandwidth and the servo bandwidth is
greater, the synchronous following will be better.
But when speed loop bandwidth + synchronous
control bandwidth > system allowable bandwidth ,
it may cause resonance of system.
Note: when increasing the speed loop bandwidth
and synchronous control bandwidth, PB03
response should faster than them.
Pr,
Pt,
S,
T
0
0
~
1023
Hz
PB43 SVL Synchronous speed error low-pass filter:
When the synchronous control is affected by low
resolution, meaning that noise (less sharp and
rough sound) is generated, you can use low-pass
filter to suppress the noise. This filter must be
faster than the synchronous control bandwidth.
Pr,
Pt,
S,
T
0
0
~
1000
0.1ms
PB44 PPD Position loop compensation
Increasing this gain value will improve the
tractability of position command.
Pr,
Pt
0
0~500 N/A
PB45
NHF4 Frequency of machine resonance suppression
filter 4
This parameter is to set the frequency of machine
resonance suppression filter, its usage is same as
PB01.
All
1000
10
~
4000
Hz
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...