It is recommended to switch speed/torque mode after the motor is completely stopped.
6.5.3 Torque/position dual mode
It has 2 types: T/Pt and T/Pr. The user can set PA01 to 1005 (T/Pt mode) or 1015 (T/Pr mode).
If the motor is running at high speed, the mode switching cannot be performed. When DO ZSP
is on, the control mode can be switched.
The user can switch the torque/position dual mode through the LOP terminal of the DI pin. If
you want to switch to position control with inner register mode, the CTRG signal need to be
turned on, you can refer to the following timing diagram for details: