323
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PC83 CMSK E-Cam master axis pulse masking setting
u z y x
x:
pulse masking function of master axis / pulse input
method of master axis
x
Fu
n
cti
o
n
Ac
tual
mast
e
r
axis pu
ls
e
V
ir
tual
mast
e
r
axis pu
ls
e
Description
0
Fu
n
cti
o
n
disabl
e
d
Ac
ce
pta
ble
Disabl
e
d
Slave axis is driven by
the actual master axis
pulse.
1
M
ast
e
r
axis
pu
lse
mask
e
d
mask
e
d
Slave
axis
stops
operating,
but
the
masked master pulse
continues to be stored in
the internal variable.
2
C
o
n
ti
n
u
o
u
s f
o
rw
ar
d
ru
n
n
in
g
E
n
abl
e
Command source is the
virtual pulse frequency
(unit: Kpps) set by
PC83.uz. This function
will
operate
continuously. To stop
the virtual pulse, set x to
1.
3
C
o
n
ti
n
u
o
u
sly
re
ve
rs
e
ru
n
n
in
g
4
Fo
rw
ar
d
JO
G
Command source is the
virtual pulse number
(unit: pulse) set by
PC83.uz. This function
only executes the pulse
number set by PC83.uz.
5
Re
ve
rs
e
JO
G
6
~
8
-
-
-
-
Pr 0000h
0h
~
FF7Dh
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...