13.3 Absolute battery specifications
Cautions for use
Carefully read the following safety cautions. Only use the specified batteries to avoid damage
or dangerous conditions.
1. Make sure the installation location is free of vapor, corrosive and inflammable gas.
2. Correctly place the battery into the battery box to avoid short-circuit.
3. Do not short circuit the positive and negative polarity of the battery, and do not install the
battery in reverse direction.
1. Do not place the battery in a high-temperature environment over 100°C (212°F) or fires, as
this may cause a fire or an explosion.
2. The batteries are non-rechargeable. Do not charge the batteries as this may result in an
explosion.
3. Do not directly weld on the surface of the battery.
Battery specifications
Material
Lithium-thionyl chloride/inorganic electrolyte battery
Type
ER6C
Shihlin model name:
SDH-BAT
Standard voltage
3.6 V
Standard capacity
1800 mAh
Continuous discharge current
100
µ
A
Dimension(D x H)
14.5 x 51 mm
Weight
15 g
Operating temperature
-55˚C~85˚C (-67˚F~185˚F)
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...