19
3.1.4 Wiring for power supply
⚫
Insulate the connection of the power terminal to avoid the possibility of
electric shock.
⚫
The power supply cable(U,V,W) of servo drive and servo motor must
be connected correctly to avoid abnormal operation on servo motor.
⚫
Servo motor cannot be connected to commercial power supply,
otherwise it may cause malfunction.
The Shihlin servo drive power wiring is three-phase power. In the following diagram, Power
ON is a contact, and Power OFF and Alarm Processing are b contacts. 1MC/a is self-retaining
power supply and 1MC is electromagnetic contactor.
200V Series:
Motor
U
V
W
DC
24
V
ALR_RY
CN
1
DO
1
(
41
)
SG
(
50
)
Servo Drive
R
S
T
L
1
L
2
Noise filter
R
S
T
ALRM
_
RY
1
MCCB
Power
On
Power
Off
1MC/a
MC