106
The servo will calculate the best gain value automatically after gain estimation. The following
table is the estimation item.
Name
Parameter
abbreviation
Parameter
code
Setting
range
Unit
Default
value
Control
mode
Resonance
suppression low-
pass filter
NLP
PB03
0~10000
0.1ms
10
Pt,Pr,S,T
Position feed-
forward gain
value
FFC
PB05
0~200
%
0
Pt,Pr
Servo motor load
inertia ratio
GD1
PB06
0~1200
0.1time
70
Pt,Pr,S
Position loop
gain
PG1
PB07
4~1024
rad/s
45
Pt,Pr
Speed loop gain
VG1
PB08
40~9000
rad/s
183
Pt,Pr,S
Speed integral
gain value
VIC
PB09
1~1000
ms
34
Pt,Pr,S
When the communication software enters the inertia estimation and analysis mode,
the panel will display the following figure:
---- This screen display means the
servo enters inertia
estimation/analysis mode
LED blinks