387
PL10
Electrical angle correction function:
x: Z phase correction function
x=1: add electrical angle which is trigged by z
phase signal with PL11 offset angle.
y: check Hall sensor move distance
y=1: if the deviation between commutation angel
detected by Hall sensor and actual electrical angle
exceeds 90 degree, AL.55 occurs.
All
0x00
0h
~
11h
N/A
PL11
Z phase signal offset angle:
When PL10.xBit=1, the electrical angle will change to
PL11 setting when z phase signal is triggered for the
first time.
All
0
0
~
3600
0.1°
(Electr
ical
angle)
PL12
Current setting for initial magnetic field detection:
If PL04.y=0, the servo drive will automatically
detect the motor magnetic field when the servo is
On for the first time, the detection current is PL12
setting value and the setting is as follows:
1. When the friction between the motor and the
mechanical parts is too large, magnetic field
detection error may occur which triggers AL.52.
Increasing the setting value of PL12 can reduce the
occurrence of AL.52.
2. When the initial magnetic field detection vibration
of the motor is too large, you can reduce the setting
value of PL12 to reduce the detection motion.
※
The initial magnetic field current detection cannot
used for the Z-axis without spring or balance
treatment.
All
100
0
~
300
%
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...