460
Drive Model Type
SDP-□□□A4C
200
300
500
700
Servo Motor type
SMP-□□□□
H180
H290
H440
H550
H750
Motor capacity
1.8K
2.9K
4.4KW
5.5KW
7.5KW
Safety function
STO
P
os
it
ion
co
nt
rol
mode
Input pulse
frequency
Line driver: 500Kpps(low speed)/8Mpps(high speed);
Open collector: 500Kpps
Command pulse
mode
CCW pulse train +CW pulse train; pulse train + sign;
AB phase pulse train.
Command source
External pulse control / Internal register setting
Smoothing
method
Low-pass filter / Linear / PS-curve smoothing
Command pulse
ratio
Electronic gear ratio A/B times A: 1~4194304, B: 1~4194304
(Limited to: 1/50 < A/B < 25600)
Deviation excess
±3
revolutions
Torque limit
Internal parameter setting or external analog input setting
(0~+10VDC/maximum torque)
Feed forward
compensation
Internal parameter setting0~200%
S
pe
ed
co
ntr
o
l mode
Speed control
range
Analog speed command 1:2000, Internal speed command 1:5000
Command source
External analog voltage input/Internal register setting
Smoothing
method
Low-pass filter / Linear acceleration/deceleration curve
/ S-curve smoothing
Analog speed
command input
0
~
±10VDC/rated speed(input
impedance 10~12kΩ)
Speed change
rate*
Load fluctuation 0~100% maximum ±0.01%
Power fluctuation ±10% maximum 0.01%
Ambient temperature fluctuation 0
℃
~55
℃
: maximum ±0. 5%(analog
speed command)
Torque limit
Internal parameter setting or external analog input setting(0~+10VDC
/maximum torque)
Bandwidth
Maximum 3KHz
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...