265
PA11 RES2
(*)
Regenerated resistor capacity
Model
Default
below 500W
20W
750W~1KW
40W
1.5KW~3KW
100W
Refer to section 14.2 for external resistor capacity.
All
Refer to
the left
table.
0
~
3000
Watt
PA12 INP In-position range:
In the position control mode, when the deviation
between the position command and the actual motor
position is less than the setting value of INP, the INP
signal of DO will output.
Model
Default value
50W~750W
167772
1KW~3KW
83886
Pt,Pr
Refer to
the left
table.
0
~
2
24
pulse
PA13 PLSS
(*)
Pulse command option
Select the type of external input pulse train.
u z y x
u: external pulse input source selection
u=0: low speed photocoupler (CN1 pin, PP, PG, NP,
NG)
u=1: high speed differential (CN1pin, HPP, HPG,
HNP, HNG)
x: input pulse train format selection
x=0:forward/reverse rotation pulse train
x=1: pulse train+sign
x=2: AB phase pulse train.
y: input pulse train logic selection
y=0: positive logic,
y=1: negative logic
Pt
0000h
0000h
~
1512h
N/A