107
4.7.
Parameter mode
4.7.1 16 bit parameter setting instruction
Some parameter changes become valid only after power cycling
(1)
Operation instruction
The following is an example to illustrate the operation method after power cycling when the
control mode (PA01) is changed to speed control mode.
Example 1: control mode(PA01)changes to speed control mode.
Press MODE button to switch to PA01 parameter.
Indicates parameter PA01
Press UP or down button to change
the parameter PA01
Press SET button twice
The rightmost parameter keeps flicking
Press UP button twice
Change the setting value during flicking
Use UP / DOWN button to change the setting
Press SET button to activate the setting
Parameter setting is completed
Press UP/DOWN to move to next parameter.
When changing PA01, changed setting is activated only after power cycling.
⚫
The MODE key is use as shift function when setting the parameters.
Next section will introduce how to use the MODE, UP and DOWN buttons to operate.