303
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PC31
MOG2 Analog monitor MON2 output proportion:
This parameter is to set the maximum proportion of
analog monitor MON2 output, its function is same as
PC30.
All
100 1~100 %
PC32
CMX2
Electronic gear numerator 2
To set the 2nd group of electronic gear numerator.
Pt
1
1
~
2
26
N/A
PC33
CMX3
Electronic gear numerator 3
To set the 3rd group of electronic gear numerator.
Pt
1
1
~
2
26
N/A
PC34
CMX4
Electronic gear numerator 4
To set the 4th
h
group of electronic gear numerator.
Pt
1
1
~
2
26
N/A
PC35
VCL
(*)
Analog speed voltage limit:
This parameter is to limit the input voltage (VC) of
the analog speed command. Setting it to 0 means no
limitation. For example, if the analog voltage of the
VC input is 10V, and PC35 is set to 5000, the drive
will calculate the VC voltage as only 5V, and this can
be used to control speed command/limit.
S,
T
0
0
~
20000
mV
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...