444
AL.27 Encoder error 4
Alarm cause
Checking method
Corrective action
The internal memory of
the encoder error.
1.
Check if the grounding
of motor is normal.
2.
Check if the encoder
signal line is separated
from the power line or
high current line to avoid
interference.
3.
Check whether the wire
of encoder has a
shielding net.
1.
Connect the U,V,W
ground terminal (green
wire) to the heat sink
base of the drive.
2.
Please separate the
encoder cable from the
motor power cables and
high current cables.
3.
Use the wire with
shielding net.
4.
If the issue persists,
send it back to the
distributor or
manufacturer.
AL.28 Encoder overheat
Alarm cause
Checking method
Corrective action
Encoder operating
temperature is higher than
95
℃
.
Put encoder away from
heat source and do not
operate in high temperature
environment.
1.
Do not operate in high
temperature
environment and wait
for the encoder board
cool down to room
temperature.
2.
If the issue persists,
send it back to the
distributor or
manufacturer.
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...