308
the value of this parameter. In this case, set PC50.Y
to 0 and then to 2 to reset this parameter to the
motor feedback position.
PC49 CMNO
(■)
Compare: number of comparing times:
When CMP is stopped
(PC44 x.Bit0 = 0)
, the
parameter indicates the number of data expected to
be compared (readable and writable).
When CMP is in operation
(PC44 x.Bit0 = 1)
, this
parameter indicates the remaining number of data to
be compared (read-only). Each time it compares one
data, the value of PC51 decrements by 1 until the
value is 0, indicating that comparing is complete.
Note: the total number of data from CAP, CMP and
E-Cam cannot exceed 800.
All
1
1
~
(800-
PC47)
N/A
PC50 CMCT
(■)
Compare: activate control
d c b a u z y x
x(HEX): activate Compare (d.Bit0=0)(DO4 is
compare output pin)
x.bit3
x.bit2
x.bit1
x.bit0
x.Bit0 =
1
Start comparing; automatically clear after finishing
comparing
PC49> 0: CMP quantity decrease to 0.
PC49= 0: automatically turn off CMP.
Note: you need turn off the CMP function to enable
writing before change the setting.
x.Bit1 =
1
Cycle mode, it will constantly reset the PC49.It
need to turn off the CMP function to stop.
x
.Bit2 =
1
After
comparing
is
completed,
activate
Capture(PC44 x.Bit0 = 1) and reset PC43 to
previously value, but this setting is invalid if
capture is already activated.
x
.Bit3 =
1
All
0064
0010h
0001
0000h
~
FFFF
312Fh
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...