131
estimated automatically, you have to manually set PB06.
The related parameters setting are as follows:
Parameter
NO
Parameter
abbreviation
Parameter name
Modifiable or auto-
estimated
PA03
ATUL
Auto-tuning response
level setting
Modifiable
PB06
GD1
Servo motor Load inertia
ratio
Modifiable
PB07
PG1
Position loop gain
Auto-estimate
PB08
VG1
Speed loop gain
Auto-estimate
PB09
VIC
Speed integral gain
Auto-estimate
5.3.3.2 Auto tuning procedure
When the user sets the servo to auto-tuning mode, the servo action is showing in the following
block diagram.
motor
One touch
tuning
Auto setting
current
control
current feedback
response
level setting
turning on when set
to 2,3,4
load inertia ratio
estimation
position, speed feedback
inertia
estimation
parameter PB06
PA03
response
level
setting
auto-tuning mode
setting
auto-tuning process
PA02
load inertia
Summary of Contents for SDP Series