314
PC65
PLED1
E-Cam: initial lead pulse before engaged:
When the condition to engage E-Cam (PC66z) is
met, the pulse number from the master axis has to
exceed the value of this parameter for the E-Cam to
fully engage. The pulse from the master axis will be
neglected if the initial lead pulse is not reached.
Parameter with + sign: need to receive forward pulse
as lead pulse.
Parameter with – sign: need to receive reverse pulse
as lead pulse.
This parameter can be written with the virtual master
axis pulse function(refer to PC83)
Pr
0
-2
30
+1
~
2
30
-1
Pulse
unit of
master
axis
PC66 ECON
(■)
E-Cam
:
activate E-Cam control:
d 0 b a u z y x
x: E-Cam function
x.bit2
x.bit1
x.bit0
x.Bit0 = 1:
E-Cam is enabled.
Note: this parameter is only writable when E-Cam
stops.
x.Bit1
0:
when the servo is off, the alarm occurs or Pr is
performing homing, the E-Cam is disengages.
1: when the servo is off or alarm occurs, the E-Cam
remains engaged. When the servo switches to on,
or some big alarm is cleared, E-Cam can operate
directly.
x
.Bit2
0: modified PC96 is effective in next engagement
1: modified PC96 is effective immediately
y: command source
y=0: Capture axis
Pr
0h
0h
~
203F
F267h
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...